Agencies | Online Services | Policies
Skip to Contents

AGIO Logo--Go to AGIO Home

Arkansas Digital Ortho Program

Arkansas GIS GatewayContact UsSearch
Go to ProgramsGo to Map GalleryGo to AGIO StaffGo to AR GIS StandardsGo to Site Map""

Introduction | Metadata | Acquisition Dates | Accuracy Assessments | FAQ | Vendor Links

ADOP Accuracy Assessments

The Arkansas Geographic Information Office is responsible for reviewing all of the digital ortho quarter quadrangle (DOQQ) files delivered to the state through the ADOP project. The review process includes a visual quality analysis, a visual comparison between the first and second generation DOQQ's, a visual check for edgematch consistency, and when time permits, a horizontal accuracy assessment. Accuracy assessments are performed following the National Standard for Spatial Data Accuracy (NSSDA). All accuracy assessments that are performed by the State Geographic Information Office will be posted to this web page.


Utilizing the NSSDA

The Federal Geographic Data Committee (FGDC) established the NSSDA in 1998. The NSSDA provides a "statistical testing" methodology for reporting the horizontal and vertical accuracy of vector and raster graphics. These methodologies enable one to compare the coordinates of an independent data set to the coordinates of the test data set to determine the horizontal or vertical accuracy of the test data set. The document below will examine the horizontal accuracy of a second-generation digital orthophoto quarter quadrangle (DOQQ) produced by Pixxures. The independent data set was created utilizing GPS methodologies and the Arkansas Mapping Grade GPS Standard. The test data set was created by heads-up digitizing points on the second-generation DOQQ. Reporting the accuracy of spatial data following a common methodology allows end-users of the spatial data to determine its usefulness.

Note: DOQQ's produced in the same project may have different accuracies, regardless of the project parameters. The elevation model, control points and other components of the DOQQ process contribute to its accuracy. Each DOQQ should be tested independently when its known accuracy is required.
Accuracy Assessment Reports

Refer to the Horizontal Accuracy Worksheet Results (located in the appendix of each report) to determine the exact horizontal accuracy. Findings have been rounded to the nearest meter in the results reported below. For example, Hope SW tested 5.49219054 m or 18.01895998 feet, which was rounded to 5 m or 18 feet.

Ashley County Mosaic - The Ashley County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 5 meters (16 feet) horizontal accuracy at a 95% confidence level.

Benton County Mosaic - The Benton County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 4 meters (13 feet) horizontal accuracy at a 95% confidence level.

Bradley County Mosaic - The Bradley County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 5 meters (16 feet) horizontal accuracy at a 95% confidence level.

Chicot County Mosaic - The Chicot County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 3 meters (10 feet) horizontal accuracy at a 95% confidence level.

Clark County Mosaic - The Clark County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 5 meters (16 feet) horizontal accuracy at a 95% confidence level.

Clay County Mosaic - The Clay County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 4 meters (13 feet) horizontal accuracy at a 95% confidence level.

Columbia County Mosaic - The Columbia County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 7 meters (23 feet) horizontal accuracy at a 95% confidence level.

Conway County Mosaic - The Conway County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 6 meters (20 feet) horizontal accuracy at a 95% confidence level.

Crawford County Mosaic - The Crawford County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 8 meters (26 feet) horizontal accuracy at a 95% confidence level.

Grant County Mosaic - The Grant County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 4 meters (13 feet) horizontal accuracy at a 95% confidence level.

Greene County Mosaic - The Greene County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 5 meters (16 feet) horizontal accuracy at a 95% confidence level.

Hempstead County Mosaic - The Hempstead County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 8 meters (26 feet) horizontal accuracy at a 95% confidence level.

Jefferson County Mosaic - The Jefferson County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 5 meters (16 feet) horizontal accuracy at a 95% confidence level.

Johnson County Mosaic - The Saline County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 10 meters (33 feet) horizontal accuracy at a 95% confidence level.

Lafayette County Mosaic - The Lafayette County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 5 meters (16 feet) horizontal accuracy at a 95% confidence level.

Miller County Mosaic - The Miller County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 9 meters (30 feet) horizontal accuracy at a 95% confidence level.

Montgomery County Mosaic - The Montgomery County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 7 meters (23 feet) horizontal accuracy at a 95% confidence level.

Nevada County Mosaic - The Nevada County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 5 meters (16 feet) horizontal accuracy at a 95% confidence level.

Pike County Mosaic - The Pike County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 6 meters (20 feet) horizontal accuracy at a 95% confidence level.

Polk County Mosaic - The Polk County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 8 meters (26 feet) horizontal accuracy at a 95% confidence level.

Prairie County Mosaic - The Prairie County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 5 meters (13 feet) horizontal accuracy at a 95% confidence level

Pulaski County Mosaic - The Pulaski County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 5 meters (16 feet) horizontal accuracy at a 95% confidence level.

Pulaski County DigitalGlobe Geotiffs - The Pulaski County DigitalGlobe Geotiffs tested 4 meters (12 feet) horizontal accuracy at a 95% confidence level.

Saline County Mosaic - The Saline County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 8 meters (24 feet) horizontal accuracy at a 95% confidence level.

Scott County Mosaic - The Scott County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 9 meters (30 feet) horizontal accuracy at a 95% confidence level.

Sebastian County Mosaic - The Sebastian County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 9 meters (30 feet) horizontal accuracy at a 95% confidence level.

Stone County Mosaic - The Sebastian County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 10 meters (33 feet) horizontal accuracy at a 95% confidence level.

White County Mosaic - The White County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 4 meters (13-feet) horizontal accuracy at 95% confidence level

Van Buren County Mosaic - The Van Buren County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 9-meters (30-feet) horizontal accuracy at 95% confidence level.

Yell County Mosaic - The Yell County Mosaic created with the second generation DOQQ's utilizing Mr. SID Encoder tested 7-meters (23-feet) horizontal accuracy at 95% confidence level.

Digital Ortho Quarter Quad NSSDA Test

Mandeville Southwest - The Mandeville SW second generation DOQQ tested 5-meters (16-feet) horizontal accuracy at 95% confidence level.

Warren Northwest - The Warren NW second generation DOQQ tested 5-meters (16-feet) horizontal accuracy at 95% confidence level.

Hope Southwest- The Hope SW second generation DOQQ tested 5-meters (16-feet) horizontal accuracy at 95% confidence level.

NOTEThese documents are in Acrobat Reader format. 
If you do not have Acrobat Reader 5.0 loaded on your computer, you must first install it in order to view or print a PDF documents.

Introduction | Metadata | Acquisition Dates | Accuracy Assessments | FAQ | Vendor Links

Security | Accessibility | ©Copyright 2004